Green Commercial buildings |
click here if you can't see the BEAR-logo |
Panda Office building
|
|
address:
|
|
![]() |
|
The office may use the ® WWF Panda
symbol because the building is constructed according
to the brief for Panda offices.The brief: Energy performance EPc < 0.75 45% less energy than the building code requires Application of a solar system DHW or PV system Sustainable Building Approach FSC-certificated wood Examination of design and construction by an independent consultant |
|
Sustainable aspects :
|
|
| |
Energy conservationEnergy performance ratio = 0,6 (60% less than the building
code requirement of 1,6) |
![]() |
|
Low energy appliancesLow energy refrigerator A type |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
Ventilation and passive coolingVentilation with heat recovery |
![]() |
|
![]() |
Application of solar energyMore glass on south |
| |
![]() ![]() |
![]() |
PV systemTailor made PV modules |
![]() |
|
![]() |
Water conservationUse of rainwater for the toiletflush |
| |
![]() |
Sustainable building materialsFacades limesandstone and brick |
|
![]() |
|
|
|
Flora and FaunaSwallow's nest boxes |
| An ecological assesment
of the building has been carried out by NIBE (Dutch
Institute for Building Biology and Ecology). NIBE used the Greencalc
method to calculated environmental sustainability of the building. GreenCalc is a computer model, developed by NIBE Consulting for office buildings and other commercial buildings. The programme is divided into four modules: materials, energy, water usage and mobility. The environmental accessment is translated into costs per m2 for the total lifecycle of the building (construction, exploitation and demolition). GreenCalc calculates the environmental costs for the materials according to the TWIN-model. In the GreenCalc calculation the module material is subdivided into raw materials, pollution, waste, environmental nuisance, ecological effect, energy, re-usability, repairability and lifespan. GreenCalc gives a clear view of the environmental cost over the different structural parts of the building and determines the total CO2-production as a result of the material usage. The module energy consists of different parameters: building use, heating-, cooling-, ventilation- and hot water system, type of artificial lighting, use of solar energy, etc. These parameters are on itself the base for the Energy performance Ratio (EPC), which is an energy efficiency calculation based on the energy consumption within the building. Calculations made with Greencalc v.2.0 give a total score on a scale from 1 - 2000. The average building built in 1990 has a score of 100 and the goal for 2050 is buildings with a score of 2000. The assesment for this building shows the result of 312.Early 2001 there are no buildings that have a better score. The highest score was 292 for a building after construction and 817 for a renovation of a building (still in design phase). |
|
The watermodule of GreenCalc calculates the effects on waterusage. Parameters are the type of sanitary, use of fresh water or the substitution of fresh water by a "grey water" circuit (use of cleaned waste water for toilet flush, garden, etc.). Mobility looks at the location of the building in relation to its environment, infrastructure, connections and distances to public transportation. |
|
![]() |
|
Go to:The exteriorThe interiorPlans and The garden |
|
Our client is: BEAR Holding BV |
|